Technical data
Rated data
Operation with increased power at a 500 V mains
4
63
EDS84ASC552 EN 9.1
Mains current at I
aN
Apparent output power
Motor power
with external
mains choke
without external
mains choke
U, V, W
4 pol. ASM
Type
I
LR
[A]
I
LR
[A]
S
aR
[kVA]
P
aR
[kW]
E84AVxxx3714
1.3
1.7
1.0
0.55
E84AVxxx5514
2.0
2.6
1.4
0.75
E84AVxxx7514
2.4
-
1.8
1.1
E84AVxxx1124
3.1
4.3
2.4
1.5
E84AVxxx1524
3.7
5.3
3.0
2.2
E84AVxxx2224
4.9
-
4.2
3.0
E84AVxxx3024xxS
6.7
-
5.5
4.0
E84AVxxx3024xx0
6.7
9.4
5.5
4.0
E84AVxxx4024
8.4
12.6
7.2
5.5
E84AVxxx5524
14.4
-
9.7
7.5
E84AVxxx7524
16.8
22.4
13.3
11
E84AVxxx1134
20.1
-
17.6
15
E84AVxxx1534
-
-
-
-
E84AVxxx1834
33.7
-
31.3
22
E84AVxxx2234
1)
40.6
-
37.8
30
E84AVxxx3034
1)
56.3
-
45.7
37
E84AVxxx3734
1)
69.8
-
56.9
45
E84AVxxx4534
1)
83.0
-
66.6
55
1)
only with external mains choke
Assignment of external mains chokes
Assignment
Type
Mains choke required
Mains choke
E84AVxxx3714
no
ELN3-1500H003-001
E84AVxxx5514
no
E84AVxxx7514
yes
ELN3-0680H006-001
E84AVxxx1124
no
E84AVxxx1524
no
E84AVxxx2224
yes
ELN3-0500H007-001
E84AVxxx3024xxS
yes
ELN3-0250H013-001
E84AVxxx3024xx0
no
ELN3-0250H013-001
E84AVxxx4024
no
ELN3-0250H013-001
E84AVxxx5524
yes
ELN3-0170H017-001
E84AVxxx7524
no
ELN3-0150H024-001
E84AVxxx1134
yes
ELN3-0088H035-001
E84AVxxx1534
-
-
E84AVxxx1834
yes
ELN3-0075H045-001
E84AVxxx2234
yes
ELN3-0055H055-001
E84AVxxx3034
yes
ELN3-0038H085-001
E84AVxxx3734
yes
E84AVxxx4534
yes
ELN3-0027H105-001