Mechanical installation – Lenze 8400 User Manual
Page 145

Mechanical installation
Standard devices in a power range of 30 ... 45 kW
Filter mounting in ”standard” technique
5
145
EDS84ASC552 EN 9.1
E84ZESx007
Proceed as follows for installation:
1. Prepare threaded holes on the mounting plate.
2. Equip threaded holes with screws and washers.
– Use 4 screw and washer assemblies or hexagon socket screws with washers.
– Do not fully tighten the screws.
3. Mount the filter onto the prepared mounting plate.
– Only tighten the screws hand-tight.
4. Mount the standard device onto the filter.
– Use 4 screw and washer assemblies or hexagon socket screws with washers.
5. If required, pre-assemble further units.
6. Adjust all units.
7. Screw all units onto the mounting plate.
– Starting torque: 7 Nm (62 lb-in)
This manual is related to the following products: