16. Click Finish.
The new calibration table is saved and applied to the next job
that prints.
Creating calibration tables with the Konica Minolta
FD-5 spectrodensitometer
This section describes how to connect and use the Konica Minolta
FD-5 spectrodensitometer to create calibration tables.
See also:
Connecting the Konica Minolta FD-5 spectrophotometer to the
IC-312 print controller
on page
Using the Konica Minolta FD-5 spectrodensitometer to create a
calibration table
on page
Connecting the Konica Minolta FD-5 spectrophotometer to the
IC-312 print controller
Before you connect the Konica Minolta FD-5 spectrodensitometer
to the IC-312 print controller, make sure that it has been calibrated
and set according to the manufacturer's specifications.
The USB cable can be connected and disconnected even when
the instrument's power is ON. In the following procedure the
instrument is turned OFF before the USB cable is connected.
1. Turn off the FD-5 by sliding the power switch to the left.
2. Connect the USB cables's B connector to the instruments's
USB connection terminal.
Creating calibration tables with the Konica Minolta FD-5 spectrodensitometer