22 film print cooling level, 23 film transfer cooling level, 24 eat disable – HID FARGO HDP5000 User Guide User Manual
Page 31: 25 enable ribbon wrinkle comp, 26 standby time, 27 beep disable, 28 i-panel heat offset, 29 holo transfer offset, 30 standby temperature, 31 mag hi-co voltage offset
![background image](/manuals/433162/31/background.png)
July 2013
Page 31 of 100
© 2012, 2013 HID Global Corporation. All rights reserved.
HDP5000 & HDPii Plus Card Printer Encoder User Guide_L000950, 3.0
4.7.22 Film Print Cooling Level
This setting controls the speed of the transfer roller-cooling fan during the printing process.
This setting should be
OFF. Turn on the InTM Print Cooling to help with splotchy color areas
on the image. Too high of a fan speed can cause smudge.
4.7.23 Film Transfer Cooling Level
This setting controls the default speed of the cooling fan for the transfer process.
In addition, the Film Transfer Cooling Level adjusts fan speeds and when they are on during
transfer. This setting affects both flash and smudge.
4.7.24 EAT Disable
This setting is an
ON or OFF switch, where 0 is off and 1 is ON. This setting is part of the
process of tracking the environmental temperature and to compensate for fluctuation.
Environmentally Adaptive Transfer (EAT) automatically adjusts the transfer temperature based
on the ambient air conditions within the printer. EAT increases or decreases the transfer roller
temperature by as much as 20C in extreme conditions.
The
EAT Disable Setting defaults to ON.
4.7.25 Enable Ribbon Wrinkle Comp
This setting is an
ON or OFF switch. Using Enable Ribbon Wrinkle Compensation turns on
extra pixels on the printhead to help mitigate ribbon wrinkle during the print process.
4.7.26 Standby Time
This setting adjusts the time until the printer goes into a reduced transfer roller temperature to
conserve energy.
A zero (
0) setting disables. Settings are in minutes.
4.7.27 Beep Disable
This setting turns off the beeping sound, suppressing audible event notification.
4.7.28 I-Panel Heat Offset
This option adjusts the heat used during the removal of unwanted InTM Film. Use minimal
adjustments. Otherwise, print ribbon and film breaks may occur.
4.7.29 Holo Transfer Offset
This option changes the Hologram Overlaminate Offset for placement parameters.
4.7.30 Standby Temperature
This option changes the temperature used when the printer is in standby mode.
4.7.31 Mag Hi-Co Voltage Offset
This changes the voltage going to the magnetic head.
Mag Hi-Co Voltage Offset is factory set. Do not change without a technician.
4.7.32 Mag Lo-Co Voltage Offset
This option changes the voltage going the magnetic head.
Mag Lo-Co Voltage Offset is factory set. Do not change without a technician.