beautypg.com

Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGEMENT User Manual

Page 283

background image

Allied Telesyn

AT-VIEW PLUS

DEVICE MANAGEMENT

Note

- AT-RG613xx : Changing the value of the Port Speed and Mode parameter will

result in the error message: "The error occurred with 'Set' operation. Error: time out
occurred." However, the new value is still set.

Note

- AT-RG634A: The current firmware version returns 'No such instance' for the

Speed parameter when the Standard sub-menu option is selected. As a result, no speed is
displayed on the RJ-45 LAN port images.

Note

- AT-RG634A: Attempting to set the Port Speed and Mode parameter under the

Additional info sub-menu option, will not result in an error but the new value will not be
applied.

Note

- AT-RG634A: Selecting the following voice port context sub-menu items will not

launch their corresponding MIB Variable Windows:

Admin Info

Dial Info

Call Forwarding Info

CLI Info

Quality Info

Statistics

Note

- AT-RG634A: Valid MIB Set values for the Receive Limit and Transmit Limit

parameters are in the range [0-1000000] inclusive. However, the current firmware version
allows these parameters to be set to more than the maximum value.

Note

- AT-RG656BD : When a LAN or WAN port is configured to auto-negotiate and is

connected to a 100Mbps full or half duplex port on another device, the current firmware
version returns '10000000' for the Speed parameter under the Standard sub-menu option.
As a result, the speed displayed on the RJ-45 LAN port images is '10' instead of '100'.

Note

- AT-RG656BD: The current firmware version returns '???(195)' for the Port Type

parameter of the 100Base-FX WAN port.

Note

- AT-RG656BD : By default, the WAN port is enabled. However, once disabled, it

can no longer be enabled until the device is reset to factory defaults.

Note

- If the user has no read access to the Admin Info MIB group, the association of the

End-Point to the Voice Port may be incorrect when accessing the different context menu
options:

Dial Info

Call Forwarding Info

CLI Info

Quality Info

Statistics

As a result, when a user right clicks on a Voice Port (eg. Tel1) and chooses any context
menu option, the information that may be shown will be for Tel2 instead.

PN 613-50665-00 Rev C

Page 283 of 294