Agent menu – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGEMENT User Manual
Page 278

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGEMENT
Agent Menu
From the Agent menu, you can view and edit the system information for the device, or log into
the CLI using Telnet.
System Info
Displays basic system information, including system name, location, contact and
description.
Note
- The current firmware version does not allow the user to enter multiple-word values
for the System Name parameter. Attempting to do so will result in the error message:
"The error occurred with 'Set' operation. Error: commit Failed."
Note
- AT-View Plus Device Manager allows the user to enter up to 188 characters for
the System Name parameter.
Note
- AT-RG634A: Setting the System Name parameter to a value that begins with a
numeric character will result in the error message: "The error occurred with 'Set'
operation. Error: commit failed."
Device Info
Displays device information such as the application version, hardware version and vendor
information.
User Info
Displays user information such as the Configuration rights, Access and Password.
Note
- AT-RG613xx: Valid MIB Set values for the Comment parameter are in the range
[0-80] inclusive. Attempting to set this parameter to a value outside the valid range will
cause the device to restart and will eventually result in the error message: "The error
occurred with 'Set' operation. Error: Time out occurred."
Note
- AT-RG613xx: Valid MIB Set values for the Password parameter are in the range
[0-79] inclusive. Attempting to set this parameter to a value outside the valid range will
cause the device to restart and will eventually result in the error message: "The error
occurred with 'Set' operation. Error: Time out occurred."
Note
- AT-RG634A: Valid MIB Set values for the Comment parameter is in the range [0-
255] inclusive. Attempting to set this parameter to a string that is more than 88 characters
long will cause the device to restart and will eventually result in the error message: "The
error occurred with 'Set' operation. Error: Time out occurred." After which, the value for
the parameter is then reverted back to its default value.
Valid MIB Set values for the Password parameter is in the range [0-255] inclusive.
Attempting to set this parameter to a string that is more than 87 characters long will cause
the device to restart and will eventually result in the error message: "The error occurred
with 'Set' operation. Error: Time out occurred." After which, the value for the parameter is
then reverted back to its default value.
PN 613-50665-00 Rev C
Page 278 of 294