Port menu – Allied Telesis AT-VIEW PLUS 3.2 DEVICE MANAGEMENT User Manual
Page 146

Allied Telesyn
AT-VIEW PLUS
DEVICE MANAGEMENT
Note
- The current firmware version is unable to provide History Control Table
information. As a result, the following error message appears: "Failed to get MIB data."
Alarm Table
Displays the RMON Alarm table.
Event Table
Displays the RMON Event table.
Event Log
Displays the RMON Event log.
Port Menu
From the Port menu, you can view and edit MIB information about the port.
Utilization
Displays the port's utilization information.
Interface Info
Displays port statistics such as the number of frames received and transmitted on the port,
bytes received and transmitted on the port, and port status.
Note
- Valid MIB Set values for the Administration Status parameter are 'up' and 'down'.
Attempting to set this parameter to any other value will result in the error message: "The
error occurred with 'Set' operation. Error: bad value."
Error Statistics
Displays error statistics.
Detail Info
Displays detailed port information such as duplex mode.
Note
- AT-View Plus Device Manager allows the user to enter up to 19 characters for the
Port Name parameter. However, the current firmware version truncates it to 16
characters.
Note
- The current firmware version allows the Port HOL Limit parameter to be set to a
value in the range [0-2147483647] inclusive.
Note
- The current firmware version does not allow the Port Back Pressure Limit
parameter to be configured.
Note
- Valid MIB Set values for the Port Flow Control parameter are 'disable' and
'enable'. Attempting to set Port Flow Control to 'unknown' will cause the parameter to be
set to 'enable'.
PN 613-50665-00 Rev C
Page 146 of 294