At-sbxpwrsys1 dc power supply – Allied Telesis AT-SBx31CFC960 User Manual
Page 230
Chapter 12: Troubleshooting
230
AT-SBxPWRSYS1 DC Power Supply
If you suspect a problem with the DC power supply, examine its LEDs.
The power supply is operating normally when the DC IN and DC OUT
LEDs are solid green and the Fault LED is off. Possible fault conditions
and their solutions are described here:
Fault Condition 1: If the DC IN LED is off, the power supply is not receiving
power, has overheated and been disabled, or has failed and needs to be
replaced. Try the following:
Verify that the power supply is installed in the correct slot in the
chassis. The AT-SBxPWRSYS1 DC Power Supply has to be
installed in slot C or D.
Verify that the On/Off switch on the power supply is in the On
position.
Verify that the DC circuit breaker is on.
Verify that the positive and negative power wires are correctly and
securely connected to the terminal block on the power supply and
circuit breaker.
Verify that the DC circuit break has power by attaching another
device to it.
Verify that the power from the DC circuit break is within the
required levels of the power supply. Refer to “Power
Specifications” on page 282.
If the chassis is still operating, use the SHOW PSU or SHOW PSU
ALL command from a local or remote management session to
determine if the power supply has overheated and shutdown.
Fault Condition 2: If the DC IN LED is solid green but the DC OUT LED is
off, the power unit is generating insufficient DC power. Replace the power
supply.
Fault Condition 3: If the Fault LED is solid amber, try the solutions in Fault
Condition 1. If they do not resolve the problem, replace the power supply.
Note
The AT-SBxPWRSYS1 DC Power Supply is hot swappable. If the
chassis contains two power supplies and one unit fails, you do not
have to power off the operational power supply when you replace
the failed unit.
Fault Condition 4: If the LEDs on the power supply indicate normal
operations but the PSU LED on the active master controller card is off or is
showing a fault condition, the problem may be with one of the two power