beautypg.com

Entering the management software commands, Figure 152: show psu command – Allied Telesis AT-SBx31CFC960 User Manual

Page 213

background image

SwitchBlade x3106 Chassis Switch and AT-SBx31CFC960 Card Installation Guide

213

Data bits: 8

Parity: None

Stop bits: 1

Flow control: None

Note

The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.

4. Press Enter. You are prompted for a user name and password.

5. Enter the default user name and password. They are “manager” and

“friend” (without the quotes), respectively

Note

User names and passwords are case sensitive.

The local management session starts and the command line interface
(CLI) prompt is displayed.

Entering the

Management

Software

Commands

To confirm the operations of the chassis with the commands in the
management software, perform the following procedure:

1. To display the status of the power supplies, enter the SHOW PSU

command.

An example of the status information is shown in Figure 152. The
power supplies are operating normally when the states are UP-UP. If
there is a problem with a power supply, refer to “AT-SBxPWRSYS1
and AT-SBxPWRPOE1 AC Power Supplies” on page 228 or
“AT-
SBxPWRSYS1 DC Power Supply” on page 230 for troubleshooting
suggestions.

Figure 152. SHOW PSU Command

2. To display the state of the fan module, enter the SHOW FANMODULE

command.

SHOW PSU

--- Power Supply Units ---

Slot Type

State

Temp (C)

A

POE

UP-UP

38

B

POE

UP-UP

38

C

System

UP-UP

38

D

System

UP-UP

38

This manual is related to the following products: