Entering the management software commands, Figure 152: show psu command – Allied Telesis AT-SBx31CFC960 User Manual
Page 213

SwitchBlade x3106 Chassis Switch and AT-SBx31CFC960 Card Installation Guide
213
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are “manager” and
“friend” (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts and the command line interface
(CLI) prompt is displayed.
Entering the
Management
Software
Commands
To confirm the operations of the chassis with the commands in the
management software, perform the following procedure:
1. To display the status of the power supplies, enter the SHOW PSU
command.
An example of the status information is shown in Figure 152. The
power supplies are operating normally when the states are UP-UP. If
there is a problem with a power supply, refer to “AT-SBxPWRSYS1
and AT-SBxPWRPOE1 AC Power Supplies” on page 228 or “AT-
SBxPWRSYS1 DC Power Supply” on page 230 for troubleshooting
suggestions.
Figure 152. SHOW PSU Command
2. To display the state of the fan module, enter the SHOW FANMODULE
command.
SHOW PSU
--- Power Supply Units ---
Slot Type
State
Temp (C)
A
POE
UP-UP
38
B
POE
UP-UP
38
C
System
UP-UP
38
D
System
UP-UP
38