6. With a #3 Phillips-head screwdriver, connect the positive (+) power
lead wire to the positive terminal on the power supply, with one of the
terminal screws removed in the previous step. The positive terminal is
on the left. You may attach the terminals with the wires either above or
below the terminal block. Figure 134 shows the positive wire above the
terminal block.
Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.
Figure 134. Connecting the Positive (+) Power Wire with a Straight
Terminal
7. With a #3 Phillips-head screwdriver, connect the negative (-) power
lead wire to the negative terminal on the power supply, with the
remaining terminal screw removed in the previous step 5. The negative
terminal is on the right. You may attach the terminals with the wires
either above or below the terminal block. Figure 135 on page 190
shows the wires above the terminal block.
Allied Telesis recommends tightening the screw to 30 to 40 inch-lbs.