beautypg.com

Allied Telesis AT-SBx31CFC960 User Manual

Page 214

background image

Chapter 10: Verifying the Hardware Operations of the Chassis

214

The module is operating normally when its state is UP-UP-ONLINE, as
shown in Figure 153. If the state of the fan module is something other
than UP-UP-ONLINE, power off the chassis and contact your Allied
Telesis representative for assistance. Do not operate the chassis
without a fully operational fan unit.

Figure 153. SHOW FANMODULE Command

3. To view the states of the controller and line cards in the chassis, use

the SHOW CARD command.

An example of the status information is shown in Figure 154. A card is
operating normally when its state is UP-UP-ONLINE. If there is a
problem with a card, refer to “Ethernet Line Cards” on page 232 or “AT-
SBx31CFC960 Controller Fabric Card” on page 240 fo
r
troubleshooting suggestions.

Figure 154. SHOW CARD Command

SHOW FANMODULE

--- Fan Module ---

Fan Module..................... FM2
Module Number.................. AT-SBxFAN06
Serial Number.................. A0428400008
State.......................... UP-UP-Online

Actual

Fan Speed

Fan 1.................. 3897 rpm
Fan 2.................. 3903 rpm

Cold Temperature Shutdown... Off

SHOW CARD

--- Card Information ---

Prov

Slot

Card Type

State

Faults

----

---------

-------------------

------

0

GE24RJ

UP-UP-Online

-

1

GE24RJ

UP-UP-Online

-

2

GE24RJ

UP-UP-Online

-

3

GE24RJ

UP-UP-Online

-

4

CFC960

UP-UP-Online (Active)

-

5

-

-

-