beautypg.com

HP Integrity rx4610 Server User Manual

Page 234

background image

Appendix A

Specifications

226

Including the BMC in the JTAG Chain

Jumper block J8D1 lets you include or exclude the BMC in the JTAG chain. By
default, the BMC is excluded from the JTAG chain.

1

A

1

B

J8D1

J8D1

Figure A-22. BMC Jumper Settings

Jumper setting diagram labeled:

A. Excludes BMC from the JTAG Chain (Default Setting)

B. Includes BMC in the JTAG Chain

Overriding the hardware PCI Hot Plug Interlock

Jumper block J1A1 lets you override the hardware PCI hot plug interlock
switches. By default, the jumper setting allows for the slot’s interlock switch
and/or the PID’s GPIO27 to set the interlock value.

1

A

J1A1

1

B

J1A1

Figure A-23. Hardware PCI Hot Plug Interlock Override Jumper Settings

Jumper settings diagram labeled:

A. Allows the PCI Hot Plug Interlock Switch and/or the PID’s GPIO27 to
Set the Interlock Value (Default Setting)

B. Overrides the Hardware PCI Hot Plug Interlock Switch