HP Integrity rx4610 Server User Manual
Page 220

Appendix A
Specifications
212
Pin
Signal
Pin Signal
Pin Signal
Pin Signal
A42 GND
A89 AD34
B42 SERR_L
B89 AD35
A43 PAR
A90 GND
B43 +3.3V
B90 AD33
A44
AD15 A91
AD32 B44
C/BE1_L
B91
GND
A45 +3.3V
A92 RESERVED B45 AD14
B92 RESERVED
A46 AD13
A93 GND
B46 GND
B93 RESERVED
A47 AD11
A94 RESERVED B47 AD12
B94 GND
Table A-14.
66MHz, 64-Bit PCI Connectors (Slots 3 through 10)
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal
A1 TRST_L
A48
GND
B1 -12V
B48
AD10
A2 +12V
A49
AD9
B2 TCK
B49
M66EN
A3 TMS
A50
GND
B3 GND
B50
GND
A4 TDI
A51
GND
B4 TDO
B51
GND
A5 +5V
A52
C/BEO_L B5 +5V
B52
AD8
A6 INTA_L
A53
+3.3V
B6 +5V
B53
AD7
A7 INTC_L
A54
AD6
B7 INTB_L
B54
+3.3V
A8 +5V
A55
AD4
B8 INTD_L
B55
AD5
A9 RESERVED A56
GND
B9 PRSNT1_L B56
AD3
A10 +3.3V
A57 AD2
B10 RESERVED B57 GND
A11 RESERVED A58 AD0
B11 PRSNT2_L B58 AD1
A12 3.3V
Keyway
A59 + 3.3V
B12 3.3V Keyway B59 + 3.3V
A13
A60 REQ64_L
B13
B60 ACK64_L
A14 RESERVED A61 +5V
B14 RESERVED B61 +5V
A15 RESET_L
A62 +5V
B15 GND
B62 +5V
A16 +3.3V
A63 GND
B16 CLK
B63 RESERVED
A17 GRANT_L
A64 C/BE7_L
B17 GND
B64 GND
A18 GND
A65 C/BE5_L
B18 REQ_L
B65 C/BE6_L
A19 RESERVED A66 +3.3V
B19 +3.3V
B66 C/BE4_L
A20 AD30
A67 PAR64
B20 AD31
B67 GND
A21 +3.3V
A68 AD62
B21 AD29
B68 AD63
A22 AD28
A69 GND
B22 GND
B69 AD61