beautypg.com

Hp server rx4610 sel data tables, Hp server rx4610 generator id codes – HP Integrity rx4610 Server User Manual

Page 175

background image

Chapter 11

Troubleshooting

167

3. Replace the DC-DC Converters.

If the HP Server’s SCSI Drives Are Not Recognized

Check the following if the SCSI drives are not recognized during POST:

1. Check the seating of the Internal SCSI Cable between the I/O Board and

the Power Distribution Board (T-Docking).

2. Check that the SCSI drives are enabled in the BIOS Setup.

If the HP Server’s IDE Drives Are Not Recognized

Check the following if the IDE drives are not recognized during POST:

1. Check the seating of the IDE cables and power cables.

2. Check that the IDE drives are enabled in the BIOS Setup.

HP Server rx4610 SEL Data Tables

The tables in this appendix provide information on the SEL viewer data on the HP
Server rx4610 server platform.

HP Server rx4610 Generator ID Codes

Generator ID

Description

20 00

BMC

28 00

CBC

C0 00

HSC