Table 11-1. BMC Beep Codes

Code

Description

1-5-1-1

FRB failure (processor failure)

1-5-2-1

No processors installed/detected

1-5-4-2

Power control fault. Power-good dropped out. This
beep code occurs during run time

1-5-4-4

PWRGD-BUF failure. System did not assert power-
good on power-up. Check installed D2D
configuration, verify processors seated, processor
power pods are connected, and Legacy cable
connector is secure with no bent pins. This beep
code ouccrs during system power on.

1-5-5-1

CPU board interlock failure. Verify CPU board
inserted fully.

1-5-4-2
OR
1-5-4-4

1

Power Supply Configuration Failed to retain 3+1
redundancy (1 Redundant)

2-1

Processor1 Power Good failed due to power pod
failure or not connected to 48V

2-2

Processor2 Power Good failed due to power pod
failure or not connected to 48V

2-3

Processor3 Power Good failed due to power pod
failure or not connected to 48V

2-4

Processor4 Power Good failed due to power pod
failure or not connected to 48V

3-1

Upper Memory board power good failed.

3-1

Lower Memory board power good failed.

4

12V D2D Power Good failure.

5-1

I/O 5V A D2D Power Good failure.

5-2

I/O 5V B D2D Power Good failure.

6

PROC 3.3V D2D Power Good failure.

7-1

I/O 3.3V A D2D Power Good failure.

7-2

I/O 3.3V B D2D Power Good failure.

8-1

1.8V D2D Power Good failure (processor board
only).