Chapter 8

Server Management Boards

102

Figure 8-10. Removing the Power Distribution Board (T-Docking)

Installing the Power Distribution Board (T-Docking)

To install the Power Distribution Board (T-Docking), complete the following
procedure:

1. Remove the U-shaped handle on the original Power Distribution Board (T-

Docking) and attach it to the replacement board.

2. Place the Power Distribution Board (T-Docking) into position, taking care

to locate the board over the indexing stake in the middle and not over the
SCSI cable.

3. Engage the connector on the side of the Power Distribution Board (T-

Docking) to the Sideplane. Be sure that the connector on the Power
Distribution Board (T-Docking) is aligned correctly with the Sideplane
before pressing the board down.