HP Integrity rx4610 Server User Manual
Page 199

Chapter 11
Troubleshooting
191
A second set of messages will be seen later in the POST, which indicates where
the memory test found errors. The sequence is as follows:
Error in memory subsystem: (Lower/Upper) Board, DIMM
XX
ERRORS FOUND IN MEMORY SUBSYSTEM. FAILING ROWS WILL
BE MAPPED OUT ON THE NEXT RESET. IT IS STRONGLY
SUGGESTED THAT YOU RESET THE SYSTEM NOW.
ALLOWING THE SYSTEM TO CONTINUE TO BOOT MAY RESULT IN
UNSTABLE SYSTEM BEHAVIOR AND/OR HARD DISK CORRUPTION.
Hit
Examples
The following examples assume that the total memory installed is 32 GB (32768
MB).
Example #1
The system boots with 32 GB of memory installed and, no defects found, will
report the following:
32768 MB Total Memory Installed
32768 MB Configured
32768 MB Tested
Example #2
Consider a system populated that has the entire upper board memory slots with 1
GB DIMMs. The first row test and the base row test passed without errors. The
extended memory test detected a memory error in DIMM 17. The following
messages will appear:
32768 MB Total Memory Installed
32768 MB Configured
32768 MB Tested
Memory Errors Detected