Chapter 10

Configuring the HP Server

115

Updating/Viewing Config Data

The Config menu contains a dynamic list of options that corresponds to the
configuration classes in the current ini file. Each configuration class in the ini
file represents a configuration item, such as EMP or PEP.

When you select an item from the Config menu, the utility reads the configuration
data of that item from the BMC and creates a setup page containing those values.
The setup pages may have drop-down boxes, edit boxes, and/or buttons. Use the
, ,

or Down arrow keys to move forward, and use or Up

arrow

keys to move backwards between each item.

Press the key while on a drop-down box to display the other options
available. Then use the arrow keys to move up or down the list. Press the

key to select an item from the drop-down box. Each item in the drop-

down boxes displays a brief description in the tip-view window. Use the
key to exit from any level of the configuration to a previous level.

Save the configuration data by selecting the button and pressing

. Use the button or key to abort changes and return

to the main window.

Platform Setup

The Platform setup page lets you configure platform-specific features, including
the accelerated cool-down period.

Accelerated Cool Down

This feature lets you enable the system to cool down more rapidly when the
system is powered off. Set the accelerated cool-down timeout in seconds. The
range is 0 to 65535 seconds. If accelerated cool-down is enabled, that is, the cool-
down time is not 0, the BMC leaves the system fans running for the specified time
after the system is powered down.