HP Integrity rx4610 Server User Manual
Page 123

Chapter 10
Configuring the HP Server
115
Updating/Viewing Config Data
The Config menu contains a dynamic list of options that corresponds to the
configuration classes in the current ini file. Each configuration class in the ini
file represents a configuration item, such as EMP or PEP.
When you select an item from the Config menu, the utility reads the configuration
data of that item from the BMC and creates a setup page containing those values.
The setup pages may have drop-down boxes, edit boxes, and/or buttons. Use the
or Down arrow keys to move forward, and use
arrow
keys to move backwards between each item.
Press the
available. Then use the arrow keys to move up or down the list. Press the
key to select an item from the drop-down box. Each item in the drop-
down boxes displays a brief description in the tip-view window. Use the
key to exit from any level of the configuration to a previous level.
Save the configuration data by selecting the
. Use the
to the main window.
Platform Setup
The Platform setup page lets you configure platform-specific features, including
the accelerated cool-down period.
Accelerated Cool Down
This feature lets you enable the system to cool down more rapidly when the
system is powered off. Set the accelerated cool-down timeout in seconds. The
range is 0 to 65535 seconds. If accelerated cool-down is enabled, that is, the cool-
down time is not 0, the BMC leaves the system fans running for the specified time
after the system is powered down.