beautypg.com

HP Integrity NonStop H-Series User Manual

Page 39

background image

INFO Command

DSNM Commands

2–14

098571 Tandem Computers Incorporated

ERROR-SUPPRESS

suppresses any response from objects that produce errors.
This option is normally used when it is known in advance
that objects will produce errors and the response is not
desired.

If you do not specify a value for the error modifier, it defaults to ERROR-BRIEF.

Considerations

The INFO command is not appropriate for all object types. See Section 5,
“Subsystems,” for information on how the command is interpreted by each subsystem.

Examples

The following command returns the configuration information for the Pathway
terminal DPWT3 under \BERLIN.$PMD with the alias TERM-3:

INFO TERM-3

A sample response to the command is:

PATHWAY TERM DPWT3 UNDER \BERLIN.$PMD

Autorestart: 0

Break: off

Diagnostic: on

Displaypages: -1

Echo: on

Exclusive: off

File: \BERLIN.$TM13B

Initial: ENABLE-RELEASE

Inspect: off

Inspectfile:

Ioprotocol: 0

Maxinputmsgs: 0

Printerattached: no

Printerfile:

Tclprog: \BERLIN.$SYSLOG.TRSYS.POBJ

TCP: TCP2

TMF: on

Termtype: CONVERSATIONAL

Termsubtype: 0

Trailingblanks: on