beautypg.com

ADC Release 3.1 User Manual

Page 444

background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-424
© 2000, ADC Telecommunications, Inc.

DLP-795

Page 2 of 11

4

SAVE DATABASES

Summary: The user should save all databases (NMIC and NE) from the slot 2 NMIC prior to
initiating the software upgrade procedure. Note that this is a precautionary measure only since
the databases are also backed up during the procedure itself. Should the NMIC disk become
corrupted for some reason, however, it’s best to have all databases saved to an external storage
medium. The following steps explain how to do this:

1. Open a new shell window or physically connect a laptop or workstation to the NMIC and

log into the slot_2 NMIC as a root user. This shell will be referred to as the “slot_2 NMIC
shell”.

telnet [IP address of slot_2 NMIC]

2. At the slot_2 NMIC shell, change to the directory in which the databases are located by

entering the following command:

cd /cellworx/config

3. Make a directory on the slot_2 NMIC used to store the Release 3.0 databases during the

upgrade by entering the following command:

mkdir release3.0_dbs

4. Copy the databases to the new directory by entering the following command:

cp NE.? NE.?? NMIC release3.0_dbs

Note: The question marks are single character wildcards. (Do not delete the
NE.default file.)

5

COPY DATABASES TO AN EXTERNAL DEVICE

Note:

This next section is optional. Having the databases stored on an external device

is an extra precaution.

5. Invoke a new shell (not a NMIC shell) on the laptop or workstation. This shell will be

referred to as the “Workstation shell”. From the Workstation shell, change to the root
directory by entering the following command:

cd / or cd \ on a PC

6. Make a directory called “cellworx” on the external workstation by entering the following

command:

mkdir cellworx