Dlp-762, Page 2 of 6, Item status definition action – ADC Release 3.1 User Manual
Page 296
1152700
•
Issue 1
•
February 2001
•
Section 2 Operations and Maintenance
Page 2-276
© 2000, ADC Telecommunications, Inc.
DLP-762
Page 2 of 6
Cellworx Vision: Card View - T3 TMUX Multi 1 Mother Card
Status:
Apply
Chassis View
Refresh
Close
X
Card Level
Operational State:
Availability State:
Protection State:
Port Level
Status
Active
Protect
1
Port
ADC
T3 TMUX
MULTI 1
Up
Available
Unknown
Line State:
Configuration:
Port Level
Recieve:
No Alarm
RCV RAI Failure
Xmt RAI Alarm
Rcv AIS
Xmit AIS
LOF
LOS
Loopback State
Rcv Test Code
Other:
Status
Active
Protect
ADC
TMUX
EXP
Slot: 3
Slot: 4
APPLIES CHANGES
AND SENDS TO SHELF
CONTROLLER.
RETURNS TO CHASSIS
VIEW WITHOUT CLOSING
CARD LEVEL VIEW.
REPAINTS WINDOW
TO REFLECT ANY
CHANGES.
CLOSES CARD LEVEL
VIEW AND RETURNS TO
SHELF LEVEL VIEW.
CLICK ON BOX AND DRAG
UP OR DOWN TO EXPAND
STATUS OR CONFIGURATION
VIEWS.
13436-B
DS3 Port
DS1 Channel
Transmit:
NE Name: Cellworx1
NE Id: 1
Card: T3 TMUX MULTI 1 / TMUX E
Slot Number: 3 / 4
Port Number: 1
Channel Number:
1
Figure 762-1. T3 TMUX Multi 1/TMUX EXP Card Status Window
Table 762-1. Display T3 TMUX Multi 1 and TMUX EXP Card Status Definitions
ITEM
STATUS
DEFINITION
ACTION
Operational
State
Up
Down
Unknown
Card is functioning properly.
Card is not functioning
properly, is in reset mode, or
failed. Check Admin state.
The shelf controller does not
currently know the
operational status.
No action required.
Verify card is installed, check for
failure indications, or provision card
for service per DLP-754.
Wait a few seconds for operations to
complete and update the screen.
(continued)