beautypg.com

Dlp-731, Page 4 of 9, Figure 731-4. ring audit window (example) – ADC Release 3.1 User Manual

Page 186

background image

1152700

Issue 1

February 2001

Section 2 Operation and Maintenance

Page 2-166

2000, ADC Telecommunications, Inc.

DLP-731

Page 4 of 9

Cellworx Vision: Ring Upgrade - Task Overview

X

1) Shutdown all other GUIs

2) Verify no ring errors

4) No reset of RICs in slot 17

5) Install new RICs in slot 16

7) Test ring 16

8) No reset of RICs in slot 16

9) Install new RICs in slot 17

11) Test ring 17

3) Configure ring upgrade

6) Verify no ring errors

10) Verify no ring erors

12) Complete ring upgrade

0026-030

Ring Upgrade - Shutdown GUIs

Cancel

X

Next>>

Please shutdown all other Cellworx Vision GUIs.

0026-031

Figure 731-2. Ring Upgrade Task Overview Widow

Figure 731-3. Shutdown Active GUI Sessions

Cellworx Vision: Ring Audit

X

Next >>

Cancel

Refresh

NE

Card Type (16) Upstream (16) Card Type (17) Upstream (17) Statu

NE 1

NE 2

NE 3

NE 4

NE 5

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

622 Ring

NE 2 Slot 16

NE 3 Slot 16

NE 4 Slot 16

NE 5 Slot 16

NE 1 Slot 16

NE 1 Slot 17

NE 5 Slot 17

NE 4 Slot 17

NE 3 Slot 17

NE 2 Slot 17

ok

ok

ok

ok

ok

Actual Ring:

NE

Upstream (16) Upstream (17)

NE 1 - Broadway

NE 2 - 17th Street

NE 3 - Northwest St.

NE 4 - Central Ave.

NE 5 - Duncan Dr.

NE 2 Slot 16

NE 3 Slot 16

NE 4 Slot 16

NE 5 Slot 16

NE 1 Slot 16

NE 1 Slot 17

NE 5 Slot 17

NE 4 Slot 17

NE 3 Slot 17

NE 2 Slot 17

Provisioned Ring:

Verify Status column
indicates "OK" for all
links.

0026-032

Figure 731-4. Ring Audit Window (example)