NORD Drivesystems BU0700 User Manual
Page 95
5.1.6 Fehler! Verweisquelle konnte nicht gefunden werden.
BU 0700 GB-1411
Subject to technical alterations
95
Parameter
Setting value / Description / Note
Available with option
P544 (P)
Bus actual value 2
always visible
0 ... 12
[ 0 ]
This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).
P545 (P)
Bus actual value 3
always visible
0 ... 12
[ 0 ]
This parameter is identical to P543.
Condition is PPO 2 or PPO 4 type (P507).
Note: For the selection (P546 = {3} or {6} (32 Bit setpoint position) (P454) is not available.
P546 (P)
Function bus setpoint 1
POS
0 ... 7
[ 1 ]
In this parameter, a function is allocated to the output setpoint 1 during bus actuation.
Note: Further details can be found in the respective BUS instruction manuals.
0 = Off
1 = Setpoint frequency (16 Bit)
2 = 16 Bit setpoint position (only with Option PosiCon, SK 700E)
3 = 32 Bit setpoint position (only with Option PosiCon, SK 700E and when PPO type 2 or 4 has been
selected)
4 = Control terminals PosiCon (only with Option PosiCon, SK 700E, 16Bit)
5 = Setpoint position (16 Bit) increment 2 (only with PosiCon SK 700E)
6 = Setpoint position (32 Bit) increment 2 (only with PosiCon SK 700E)
7 = Bus IO In Bits 0-7
P547 (P)
Function bus setpoint 2
always visible
0 ... 20
[ 0 ]
In this parameter, a function is allocated to the output setpoint 2 during bus actuation.
NOTE:
Further details can be found in the respective BUS operating instructions or in the
description of P400.
0 = Off
1 = Setpoint frequency
2 = Torque current limit
3 = Actual frequency PID
4 = Frequency addition
5 = Frequency subtraction
6 = Current limit
7 = Maximum frequency
8 = Actual PID frequency limited
9 = Actual PID frequency monitored
10 = Torque
11 = Torque precontrol
12 = Control terminals PosiCon (with PosiCon option only)
13 = Multiplication
14 = Process controller actual value
15 = Setpoint process controller
16 = Process controller precontrol
17 = Bus IO In Bits 0-7
18 = Curve travel calculator
19 = Set relay (P541)
20 = Set analog output (P542)
P548 (P)
Function bus setpoint 3
always visible
0 ... 20
[ 0 ]
This parameter is identical to P547. It is only present when P546
3.
P549
Pot Box Function
always visible
0 ... 13
[ 1 ]
In this parameter, a function is assigned to the potentiometer value output when control is via the
potentiometer option. (An explanation can be found in the description of P400)
0 = Off
1 = Setpoint frequency
2 = Torque current limit
3 = Actual frequency PID
4 = Frequency addition
5 = Frequency subtraction
6 = Current limit
7 = Maximum frequency
8 = PID limited current frequency
9 = PID supervised current frequency
10 = Servo-ModeTorque
11 = Pre-tension torque
12 = No function
13 = Multiplication