5.1.5 Control terminals

BU 0700 GB-1411

Subject to technical alterations

85

Parameter

Setting value / Description / Note

Available with option

P434 (P)

Relay function 1

BSC STD MLT BUS

0 ... 38

[ 1 ]

Functions for the signal relay 1 (Control terminals 1 / 2)

The settings 3 to 5 and 11 work with 10% hysteresis, i.e. the relay contact closes (fct. 11 opens) when
the limit value is reached and opens (function 11 closes) when a 10% smaller value is undershot.

Setting / Function

Relay contact ... for

limit value or

function

(see also P435)

0 = No function

open

1 = External brake, to control a brake on the motor. The relay switches at a

programmed absolute minimum frequency (P505). A setpoint delay should be
programmed for typical brakes (see P107).

A mechanical brake can be directly AC switched. (Please note the technical
specifications of the relay contacts)

Closes

2 = Inverter is working, the closed relay contact indicates voltage

FI output (U - V - W).

Closes

3 = Current limit, based on the setting of the motor rated current in P203. This

value can be adjusted with the standardisation (P435).

Closes

4 = Torque current limit, based on motor data settings in P203 and P206.

Signals a corresponding torque load on the motor. This value can be adjusted
with the standardisation (P435).

Closes

5 = Frequency limit, based on motor nominal frequency setting in P201. This

value can be adjusted with the standardisation (P435).

Closes

6 = Level with setpoint, indicates that the FI has completed the frequency

increase or decrease. After the contact has closed, the setpoint must change
by at least 1Hz

setpoint value not reached, contact opens

Closes

7 = Fault, general error message, error is active or not yet acknowledged.

Operational

– closes

(Note: Ready does not automatically mean "Ready for switch-on")

Opens

8 = Warning; total warning, a limit value was reached that could lead to a later

shutdown of the FI.

Opens

9 = Overcurrent warning, min. 130% FI nominal current for 30 sec.

Opens

10 = Motor overtemperature motor: The motor temperature is evaluated via a

digital input.  Motor is too hot. Warning occurs after 1 seconds, overheating
switch off after 2 seconds.

Opens

11 = Torque current limit (warning), The limit value in P112 / P536 is reached. A

negative value in P435 inverts the reaction. Hysteresis = 10%.

Opens

12 = Value of P541, using parameter P541 (Bit 0), the relay can be controlled

independently of the actual operating status of the FI.

Closes

13 = Torque current limit generally active with ISD control: Limit value in P112

has been reached in the generator range. Hysteresis = 10%; Torque limit gen.
active

Closes

14 = ... 29 reserved

---

30 = Bus IO In Bit 0 / Bus In Bit 0

Closes

31 = Bus IO In Bit 1 / Bus In Bit 1

Closes

32 = Bus IO In Bit 2 / Bus In Bit 2

Closes

33 = Bus IO In Bit 3 / Bus In Bit 3

Closes

34 = Bus IO In Bit 4 / Bus In Bit 4

Closes

35 = Bus IO In Bit 5 / Bus In Bit 5

Closes

36 = Bus IO In Bit 6 / Bus In Bit 6

Closes

37 = Bus IO In Bit 7 / Bus In Bit 7

Closes

38 = Output via BUS

Closes