3.1 Technology unit

BU 0700 GB-1411

Subject to technical alterations

29

Parameter

Setting value / Description / Note

P1005

Scaling factor

The first value on the list displayed is scaled using the standardisation factor. If this standardisation
factor varies from a value of 1.00, then the units of the scaled value are hidden in the display.
Value range: -327.67 to +327.67; resolution 0.01

Parameterisation

Parameter

Setting value / Description / Note

P1101

Object selection

Selection of the item to be parameterised.
The ongoing parameterisation process relates to the object selected. Only the devices and storage
objects detected during the bus scan are displayed in the selection list.
Value range: FI, S1 ... S5

Parameter administration

Parameter

Setting value / Description / Note

P1201

Copy - Source

Selection of the actual source object to be copied.
In the selection list, only the frequency inverters and storage media detected during the bus scan
are shown.
Value range: FI, S1 ... S5

P1202

Copy - Destination

Selection of actual target object to copy.
In the selection list, only the frequency inverters and storage media detected during the bus scan
are shown.
Value range: FI, S1 ... S5

P1203

Copy - Start

This parameter triggers a transfer process, whereby all the parameters selected in >Copy

Source< are transferred to the object specified in the >Copy

– Target< parameter.

While data is being overwritten, an information window appears with acknowledgement. The
transfer starts after acknowledgement.

P1204

Load default values

In this parameter, the default settings are written to the parameters of the selected item.
This function is particularly important when editing storage objects. It is only via this parameter that
a hypothetical inverter can be loaded and processed with the ParameterBox.
Value range: FI, S1 ... S5

P1205

Clear memory

In this parameter the data in the selected storage medium is deleted.
Value range: S1 ... S5

Options

Parameter

Setting value / Description / Note

P1301

Language

Selection of languages for operation of the ParameterBox
Available languages:

German

English

Dutch

French

Spanish

Swedish

P1302

Operating mode

Selection of the operating mode for the ParameterBox
Offline:
The ParameterBox is operated autonomously. The data set of the frequency inverter is not
accessed. The storage objects of the ParameterBox can be parameterised and administrated.
Online:
A frequency inverter is located at the interface of the ParameterBox. The frequency inverter can be
parameterised and controlled.

When changing to the “ONLINE” operating mode, a bus scan is

started automatically.
PC slave:
Only possible with the p-box or SK PAR-.. ParameterBox.

P1303

Auto-bus-scan

Setting the switch-on characteristics.
Off
No bus scan is carried out; the frequency inverters connected before disconnection are sought
when switched on again.
On
A bus scan is carried out automatically when the Parameter Box is switched on.