Functions of the ParameterBox
LCD display
Graphic-capable, backlit LCD display for displaying operating values and parameters for the connected
inverter and ParameterBox parameters.
Using the SELECTION keys to toggle between the menu levels and menu items.
Press the
and
keys together to go back one level.
The contents of individual parameters can be altered with the VALUES keys.
Press the
and
keys together to load the default values of the parameter selected.
When controlling the inverter using the keyboard, the frequency setpoint is set using the VALUE keys.
Press the ENTER key to select a menu group or accept the changed menu item or parameter value.
Note: If a parameter is to remain, without a new value being stored,
then one of the SELECTION keys
can be used for the purpose.
If the inverter is to be controlled directly from the keyboard (not control terminals), then the actual setpoint
frequency can be stored under the Jog Frequency parameter (P113).
START key for switching on the frequency inverter.
Note:
Can only be used if this function
has not been blocked in parameter
P509 or P540.
STOP key for switching off the frequency inverter.
The direction of rotation of the motor changes when the
DIRECTION key is operated. Rotation direction left is
indicated by a minus sign.
Attention! Take care when operating pumps, screw
conveyors, ventilators, etc.
The LED's indicate the actual status of the ParameterBox.
DS
(ON (green))
The ParameterBox is connected to the power supply and is operational.
DE
(ERROR (red))
An error has occurred while processing data or in the connected frequency inverter.
DS
DE