P1304, P1305, P1306 – NORD Drivesystems BU0700 User Manual
Page 30: P1307, P1308
NORDAC SK 700E Operating Manual
30
Subject to technical alterations
BU 0700 GB-1411
Parameter
Setting value / Description / Note
P1304
Contrast
Contrast setting of the ParameterBox display
Value range: 0% ... 100%; Resolution 1%
P1305
Set password
The user can set up a password in this parameter.
If a value other than 0 has been entered in this parameter, then the settings of the ParameterBox or
the parameters of the connected inverter cannot be altered.
P1306
Box password
If the Password function is to be reset, the password selected in the >Set Password< parameter
must be entered here. If the correct password has been selected, than all functions of the
ParameterBox can be used again.
P1307
Reset Box parameter
In this parameter the ParameterBox can be reset to the default setting. All ParameterBox settings
and the data in the storage media will be deleted.
P1308
NORDAC p-box
Displays the software version of the ParameterBox (NORDAC p-box). Please keep for future use.
3.1.1.2 ParameterBox error messages
Display
Error
Cause
Remedy
Communication error
200
INCORRECT PARAMETER NUMBER
These error messages are due to EMC interferences or differing software
versions of the subscribers.
Check the software version of the ParameterBox and that of the connected
frequency inverter.
Check the cabling of all components, regarding possible EMC interference
201
PARAMETER VALUE CANNOT BE CHANGED
202
PARAMETER OUTSIDE VALUE RANGE
203
FAULTY SUB INDEX
204
NO ARRAY PARAMETERS
205
WRONG PARAMETER TYPE
206
INCORRECT RESPONSE RECOGNITION
USS INTERFACE
207
USS INTERFACE CHECKSUM FAULT
Communication between inverter and ParameterBox is disrupted (EMC), safe
operation cannot be guaranteed.
Check the connection to the frequency inverter. Use a shielded cable between
the devices. Route the BUS leads separately from the motor cables.
208
FAULTY STATUS RECOGNITION USS
INTERFACE
Communication between inverter and ParameterBox is disrupted (EMC), safe
operation cannot be guaranteed.
Check the connection to the frequency inverter.
Use a shielded cable between the devices. Route the BUS leads separately
from the motor cables.
209_1
INVERTER DOES NOT RESPOND
The ParameterBox is waiting for a response from the connected frequency
inverter. The waiting time has elapsed without a response being received.
Check the connection to the frequency inverter.
The settings of the USS parameters for the frequency inverter were changed
during operation.