NORD Drivesystems BU0700 User Manual
Page 31
3.1 Technology unit
BU 0700 GB-1411
Subject to technical alterations
31
Display
Error
Cause
Remedy
Identification error
220
UNRECOGNISED DEVICE
Device ID not found.
The connected inverter is not listed in the database of the ParameterBox; no
communication can be established.
Please contact your Getriebebau Nord dealership.
221
SOFTWARE VERSION NOT RECOGNISED
Software version not found.
The software of the connected inverter is not listed in the ParameterBox
database, no communication can be set up.
Please contact your Getriebebau Nord dealership.
222
CONFIGURATION STAGE NOT
RECOGNISED
An unknown component has been detected in the frequency inverter (Customer
unit / Special extension unit).
Please check the components installed in the frequency inverter
If necessary check the software version of the ParameterBox and the
frequency inverter.
223
BUS CONFIGURATION HAS CHANGED
A different device to that saved responds when the last bus configuration is
restored.
This error can only occur if the parameter >Auto. Bus Scan< is set to OFF and
another device has been connected to the ParameterBox.
Activate the Automatic Bus Scan function.
224
DEVICE NOT SUPPORTED
The inverter type entered in the ParameterBox is not supported!
The ParameterBox cannot be used with this inverter.
225
THE CONNECTION TO THE INVERTER IS
BLOCKED
Access to a device that is not online (previously Time Out error).
Carry out a bus scan via the parameter >Bus Scan< (P1001).
ParameterBox operating error
226
SOURCE AND TARGET ARE DIFFERENT
DEVICES
Copying objects of different types (from / to different inverters) is not possible.
227
SOURCE IS EMPTY
Copying of data from a deleted (empty) storage medium
228
THIS COMBINATION IS NOT PERMITTED
Target and source for the copying function are the same. The command cannot
be carried out.
229
THE SELECTED ITEM IS EMPTY
Parameterisation attempt of a deleted storage medium
230
DIFFERENT SOFTWARE VERSIONS
Warning
Copying objects with different software versions can lead to problems when
transferring parameters.
231
INVALID PASSWORD
Attempt to alter a parameter without a valid Box password being entered in
parameter >Box Password< P 1306.
232
BUS SCAN ONLY WHEN IN ONLINE MODE
ONLINE
A bus scan (search for a connected frequency inverter) is only possible when in
ONLINE mode.