2 parameter overview, user settings – NORD Drivesystems BU0700 User Manual
Page 103
5.2 Parameter overview, User settings
BU 0700 GB-1411
Subject to technical alterations
103
5.2 Parameter overview, User settings
(P)
Parameter set-dependent, these parameters can be differently adjusted in 4 parameter sets.
Parameter
No.
Name
Factory
setting
Setting after commissioning
P 1
P 2
P 3
P 4
OPERATING DISPLAYS (5.1.1)
P000
Operating display
P001
Select of displayed value
0
P002
Display factor
1.00
BASIC PARAMETERS (5.1.2)
P100
Parameter set
0
P101
Copy parameter set
0
P102
(P) Acceleration time [s]
2.0/ 3.0/ 5.0
P103
(P) Deceleration time [s]
2.0/ 3.0/ 5.0
P104
(P) Minimum frequency [Hz]
0.0
P105
(P) Maximum frequency [Hz]
50.0
P106
(P) Ramp smoothing [%]
0
P107
(P) Brake reaction time [s]
0.00
P108
(P) Disconnection mode
1
P109
(P) DC brake current [%]
100
P110
(P) Time DC-brake on
2.0
P111
(P) P factor torque limit [%]
100
P112
(P) Torque current limit [%]
401 (OFF)
P113
(P) Jog frequency [Hz]
0.0
P114
(P) Brake delay off [s]
0.00
MOTOR DATA / CHARACTERISTIC CURVE PARAMETERS (5.1.3)
P200
(P) Motor list
0
P201
(P) Nominal frequency [Hz]
50.0 *
P202
(P) Nominal speed [rpm]
1385 *
P203
(P) Nominal current [A]
3.60 *
P204
(P) Nominal voltage [V]
400 *
P205
(P) Nominal power [W]
1.50 *
P206
(P) Cos phi
0.80 *
P207
(P) Star Delta connection
0 *
P208
(P) Stator resistance [
]
4.37*
P209
(P) No load current [A]
2.1 *
P210
(P) Static boost [%]
100
P211
(P) Dynamic boost [%]
100
P212
(P) Slip compensation [%]
100
P213
(P) ISD control loop gain [%]
100
P214
(P) Torque precontrol [%]
0
P215
(P) Boost precontrol [%]
0
P216
(P) Time boost precontrol [s]
0.0
P217
(P) Oscillation damping [%]
10
P218
Modulation depth [%]
100
*) dependent on inverter power or P200