10.1 How to use SITE SETUP function (SITE SETUP page)
10.1.1 SITE MEMORY: when registering data which are set and calibrated
on the page
[Operation]
(1) Select “SITE MEMORY” by press-
ing the
or
key on the SITE
SETTING page.
Press the
ENT
key, and the “SITE
MEMORY” screen is displayed.
To return to the “SITE SETTING”
screen, press the
ESC
key.
(2) Move the cursor to “MODE” and press
the
ENT
key. The mode selection screen
will appear.
When pressing the
ENT
key after mode
selection, the relevant mode is deter-
mined.
(3) Select “SELECTION” to read out the
data, “REGISTRATION” to register the data and “DELETE” to delete the data.
“SITE MEMORY” allows you to register data which are set and calibrated on the “SITE
SETUP” page to the memory of the main unit.
When measurements are performed repeatedly in the same pipe, registered data can be loaded
to help you in achieving measurements. Up to 32 registrations of data can be made to the
memory.
Registration data: Establish setting, zero point adjustment, unit of output, output control.
Reads out the
contents of setting.
Stores the contents
of setting in memory.
Deletes the contents
of setting.
ENT
ESC
Bulletin F-9-PUX2