9. START MEASURING
When wiring, piping settings and mounting of the sensor are completed, start the measurement.
The contents displayed on the measurement screen are as follows.
• On the measurement screen, instantaneous fl ow, instantaneous fl ow velocity, integrated fl ow rate,
analog output, and analog input are displayed.
Of the 3 stages displayed on the MEASURE screen, contents can be arbitrarily allocated. Alloca-
tion is accomplished by selection of “measurement kind (fl ow rate, velocity, total, etc.)”.
If the fl ow rate is displayed when water fl ow stops, refer to page 66, “ZERO ADJUSTMENT” and
page 72, “CUT OFF”.
If the fl ow display fl uctuates, refer to page 70, “DAMPING”.
• Integrated fl ow rate value is available in the range from 0000000000 to 9999999999. If the value
exceeds 9999999999, it returns to the preset value.
• Move the cursor on the measurement screen using the
,
,
and
keys.
(1) Clock
(7) Site name
Display 1
Cursor
Display 2
Display 3
(10) Measure-
ment
kind
(10) Measure-
ment
kind
(10) Measure-
ment
kind
(2) SD memory card
(6) Battery
(4) Analog input/output
(5) Indicator
(8) Quick logger
(13) Switching measure-
ment
screen
(15) Totalize reset
(9) Status display
(14) Status display of
totalize
(12) Unit of totalize
(11) Unit of flow rate
(3) Measurement mode
Bulletin F-9-PUX2