beautypg.com

Eol resistance, From the sub-options list, click eol resistance, Click one of the add buttons – Avigilon Access Control Manager - Avigilon Workflow Guide User Manual

Page 35

background image

31

EOL Resistance

End-of-line resistance refers to resistance levels that must be maintained for input points. Input

devices used with doors from vendors, such as Mercury Security, measure resistance, in ohms, on

the circuit. This corresponds to a steady state. If the resistance drops across the circuit, an alarm is

sent back to the Access Control Manager.

To define a resistance level:

1. From the icon task bar on the home page, click Physical Access.
2. From the sub-options list, click EOL Resistance.
3. The EOL Resistance Listing page appears like this example:

4. Click one of the add buttons.

• If this is a normal circuit, use the Normal

button.

• If this is a complex circuit, use the Advanced

button.

The appropriate EOL Resistance Add page appears like these examples:

5. Enter information on this page as required.

These fields include:

Name

Enter the name you want to give this input point.

Address

Select from the drop-down list the address you want to assign this
input point.

Normal EOL Resistance

Inactive Range

Select from the drop-down list the beginning value of the inactive
range.
Values range from 100 to 9950 ohms in 50-ohm increments.

5

Normal

Advanced