beautypg.com

Avigilon Access Control Manager - Avigilon Workflow Guide User Manual

Page 27

background image

23

Offline Mode

Specifies the entry mode used for the door if the door
controller is no longer communicating with the panel.

Note: In many cases, the limited memory of most readers in offline

mode requires a very simple solution to entry or exit, such as
use of a facility code.

Select the Offline Mode option from the drop-down list.

Custom mode

From the drop-down list, select the special mode to use during
a time zone specified in the 'Custom Schedule' field. For
example, during normal working hours, it might only be
necessary to use a card only entry at a particular door,
whereas after midnight, you would enforce PIN code and card.

Custom
Schedule

From the drop-down list, select the interval during which the
custom mode specified above is activated. Only those time
zones previously defined for this system appear in this list.

Mask Forced
During

From the drop-down list, select the time during which this door
is masked even when a forced open condition is detected.
Only those schedules previously defined for this system
appear in this list.

Mask Held
During

From the drop-down list, select the time during which Door
Held Open alarms from this door will be masked. Only those
schedules previously defined for this system appear in this list.

Always Mask
Forced

From the drop-down box, select TRUE to specify that Door
Forced Open alarms at this door are always masked. Normally,
this box is blank.

Always Mask
Held

From the drop-down box, select TRUE to specify that Door
Held Open alarms at this door are always masked. Normally,
this box is blank.

Door Processing Attributes

Log Grants Right
Away

When this box is checked, the system logs an extra event as
soon as there is a grant (that is, before entry / no entry is
determined). This event is not turned into a Access Control
Manager event. Check this box in order to initiate local I/O in
the panel using the panel triggers.
Certain customers may have a trigger they want to fire (to
execute a macro) as soon as there is a grant, but before  entry
/ no entry is determined.

Deny Duress

If a user indicates duress at a door, checking this box denies
access.

Don't Pulse Door
Strike on REX

Check this box to disable the pulse of the door strike output
when the request-to-exit button is pressed. This can be used
to effect a 'quiet' exit.  If this box is not checked, the output is
pulsed.

Require Two
Card Control

Check this box to specify that two tokens are required to open
this door. This enforces two-person rule at a specified door.