Avigilon Access Control Manager - Avigilon Workflow Guide User Manual
Page 117
113
Sub-Panel
Status
Indicates the number of the sub-panels attached to this panel. Each relevant subpanel is
displayed together with its current status. The color indicates the current status.
Subpanel
The name of this subpanel. To drill down into the inputs and outputs associated with this
subpanel, click this link.
C
Status of communications between the panel and specified sub-panels. The color indicates
the current status.
P
Indicates the status of the power on this panel. The color indicates the current status.
T
Indicates the status of the tamper switch on this panel. The color indicates the current
status.
Installed
The status of the sub-panel's installation:
or
. This field is selectable and can be
toggled.
Input
This column lists all the inputs controlled by this subpanel, with the name and address of
each input.
Cmd
If allowed, one or more functions that can be performed on the input. The possible functions
are:
- Click this button to mask the specified input.
- Click this button to unmask a previously masked input.
Output
This column lists all the outputs (including relays and locks) controlled by this subpanel, with
name and address of each output.
Cmd
If allowed, click one or more of these functions that can be performed on the output.
The possible functions are:
- Click this button to power the output. If this output is a door, it energizes the circuit.
- Click this button to turn off the power to this output. If this output is a door, it de-
energizes the circuit.
- Click this button to alternately energize and de-energize this output. The pulse
interval is determined by the output’s settings.