Pin designations and voltage readings, Testing the flow meter cable – Seed Hawk Raven 2010 User Manual
Page 221
Manual No. 016-3001-003
211
Pin Designations and Voltage Readings
The following tables show the following pin designations and voltage readings.
Note:
In a non-CAN system if a +5 voltage reading is not present, disconnect the Speed Sensor cable. If
the voltage reading is restored, test the Speed Sensor cable as described in
Appendix G, Testing
the Speed Sensor Extension Cable.
Testing the Flow Meter Cable
1.
Press Product Control.
2.
Press the Data Box 2.
3.
Enter the number ‘1’ in the Meter Cal field and press OK.
4.
Press Tally Registers.
Pin Location
Designation
2 o'clock
Ground
10 o'clock
Power
6 o'clock
Signal
Pin Connections
Voltage
2 o'clock to 6 o'clock
+5 Volts
10 o'clock to 2 o'clock
+5 Volts