Troubleshooting the Viper Pro System
GPS Error Messages
No Rx file chosen
for this product
• VRC was selected for the
product during the
product setup, but no Rx
map was loaded
• Un-select the VRC selection or load an Rx map for the
product.
No Rx rate field
chosen for product
• VRC was selected and
an Rx map was loaded,
but a selection was not
made in the Rate field
• Select the appropriate item from the Rate field.
When VRC is
checked, a
Prescription File and
Rate Field must be
supplied
• VRC was selected during
the product setup, but a
prescription map and rate
field have not been
selected
• Press Browse to select the appropriate prescription
file. Select the appropriate rate item in the Rate field.
Color templates are
available only when
VRC is selected
• You selected a color
template without
selecting VRC
• You can only select a color template when you have
selected VRC and have loaded a prescription map.
Issue
Possible Cause
Solution
No GPS Coverage
warning
• You must have GPS
coverage to start a non-
VRC (Variable Rate
Control) job
• Make sure that the GPS data is being received by the
Viper system.
Warning: You do not
have optimum GPS
coverage. Some
features may be
disabled.
• GPS reception does not
have differential
correction. Therefore,
some features, such as
guidance, will not be
available when starting a
job in this condition
• Enable the differential correction function in the GPS
receiver. Contact the receiver manufacturer for
additional information.
No Differential
• Differential GPS has not
been detected by Viper
• Check the GPS receiver to make sure that it has the
differential correction function. Contact the
manufacturer for additional information.
No GPS
• Viper does not detect a
GPS signal
• Make sure that the GPS receiver is turned on and
receiving a signal.
• Make sure that the port setting for Viper and the GPS
receiver match.
• Make sure that the required NMEA messages are
turned on in the GPS receiver.
Issue
Possible Cause
Solution