Sectional Control Technology™ (SCT)
4.
Each product enabled will resume application at the target rate for the programmed override countdown
before the SCT system will resume normal application control.
SCT Ready Switchbox Setup
Touch the Next button on the Section Control Setup screen to display the Switchbox Setup screen. This
screen is used to configure the function of each section switch on the Seed Hawk switch box.
Note:
Settings on the Switchbox Setup screen are locked during job applications. Be sure the Switchbox
Setup screen is properly configured for applications before starting or resuming job applications.
In SCT Ready mode, the drill must be configured in either one, two, or five sections.
Openers
Note:
In SCT Ready mode, the soil openers are controlled manually across the entire drill width.
While operating in SCT Ready mode, the openers option must be selected to allow the Viper Pro to create an
as-applied map products dispensed from the air cart.
Meter Gates
In SCT Ready mode, each of the air cart product bins are controlled as a single product and the products will
be applied across the entire implement width. In this mode, the meter gates options on the Switchbox Setup
screen only selects the products for which the Viper Pro will create an as-applied map. Meter gates settings
should only be disabled for product bins which are not used during an application.
For Example:
If only the Meter Gate 1 option is enabled, the Viper Pro will only create an as-applied map for that product. As-
applied maps will not be created for products dispensed from bins 2 and 3.