beautypg.com

Configuring sct control, Enabling sectional control override – Seed Hawk Raven 2010 User Manual

Page 144

background image

Chapter 7

134

Seed Hawk™ Viper Pro™ Installation & Operation Manual

Note:

The time set as the override seconds does not start until the master switch returns to the on
position. Hold the master switch in the override position to sustain the override countdown if
desired.

Turn-Off % Coverage

This value controls the percentage of the section width that must be inside a previously applied area in order

for the section to turn off. The default value is 80%. This would require that 80% of a section be in a previously

applied area before SCT would turn off that section.

Note:

If the value is set to 0%, the section will not turn off automatically.

Configuring SCT Control

1.

Press the Section Status area in the main Viper screen. The Section Control Setup screen displays.

2.

Using the screen keyboard, enter a value, in seconds, in the ‘Turn-OnLook-Ahead field.

3.

Using the screen keyboard, enter a value, in seconds, in the ‘Turn-Off’ Look-Ahead field.

4.

Using the screen keyboard, enter a value, in percentage, in the ‘Turn-Off% Coverage field.

5.

Using the screen keyboard, enter a value, if desired, in seconds, in the Sectional Control Override Sec

field.

Enabling Sectional Control Override

1.

While in a job, press the Section Status area on the main screen. The Section Control Setup screen

displays.

2.

Using the on-screen keypad, enter a value, in seconds, in the Sectional Control Override Sec field.

3.

During application, toggle the master switch on the Seed Hawk switch box to the ‘OVERRIDE’ position.

Note:

The override feature affects all enabled products. The time set as the override seconds does not
start until the master switch returns to the on position. Hold the master switch in the override
position to sustain the override countdown if desired.