beautypg.com

Configuring sct control, Enabling sectional control override – Seed Hawk Raven 2010 User Manual

Page 149

background image

7

Manual No. 016-3001-003

139

Sectional Control Technology™ (SCT)

Configuring SCT Control

1.

Press the Section Status area in the main Viper screen. The Section Control Setup screen displays.

2.

Using the on-screen keypad, enter the desired time, in seconds, for the meter gates, openers, and liquid

valve ‘Turn-OnLook-Ahead fields.

3.

Using the on-screen keypad, enter the desired time, in seconds, for the meter gates, openers, and liquid

valve ‘Turn-Off’ Look-Ahead fields.

4.

Using the on-screen keypad, enter the percentage of acceptable overlap in the ‘Turn-Off% Coverage

field.

5.

Using the on-screen keypad, enter the time, in seconds, in the Sectional Control Override Sec field which

the SCT system should override product application.

Enabling Sectional Control Override

1.

While in a job, press the Section Status area on the main screen. The Section Control Setup screen

displays.

2.

Using the on-screen keypad, enter a value, in seconds, in the Sectional Control Override Sec field.

3.

During application, toggle the master switch on the Seed Hawk switch box to the ‘OVERRIDE’ position.

Note:

The time set as the override seconds does not start until the master switch returns to the on
position. Hold the master switch in the override position to sustain the override countdown if
desired.

The override feature affects all enabled products.

4.

Each product enabled will resume application at the target rate for the programmed override countdown

before the SCT system will resume normal application control.