beautypg.com

Threshold controls, Profile recording controls – Watlow ANAWIN 2 User Manual

Page 67

background image

Using the Trend Plot Screen

AnaWin User’s Guide 7-5

Threshold Controls

Use the following threshold controls to set up to three threshold levels.

Compute Now: Click Compute Now to compute the duration (in
seconds) above the threshold values and the peak temperature. Both
calculations apply only to data displayed on the graph.

Display on Graph: Select Display on Graph to display the threshold
levels on the trend plot. Deselect Display on Graph for no display of
threshold levels.

Threshold (#1, #2, #3): Use the Threshold fields to enter up to three
threshold values.

Profile Recording Controls

Use the following profile recording controls to define a profile—a
subset of plot data defined by when you start and stop recording.
Profiles are useful for oven performance comparisons.

Start: Click Start to start the profile recording.

Stop: Click Stop to stop the profile recording.

Offsets: Click Offsets to display the Reference Loop Setup window,
shown in Figure 7-3. Use this window to set up the offsets of reference
loops to be used for profile recording.

For example, consider a case in which T/C sensors are attached to a
board moving through a reflow oven. Offsets refer to the sensor
locations on a PCB relative to an arbitrary zero position.

When you are done setting reference loops, click OK to save your
settings and return to the Trend Extras window.

FIGURE 7-3

Reference Loop Setup Window