beautypg.com

21 erase a test record procedure, Table 11.0, Erase a test record procedure – Vanguard Tri-Phase User Manual

Page 82

background image

TRI-PHASE OPERATING™ INSTRUCTIONS

82


16.21 Erase A Test Record Procedure

The following procedure allows the operator to erase a test record from FLASH EEPROM memory.

Table 11.0

Erase A Test Record Procedure

STEP DESCRIPTION

DISPLAY

ACTION

1

Select “Setup” from the “Main
Menu”

1.RUN TEST

.

2.SETUP
3.TEST PLAN
4.DIAGNOSTIC
TIME: 20:15:00
DATE: 07/16/08

Press key number 2
Selection of 2 may be
made by turning the
Control Knob. Push
down Control Knob
after 2 is selected

2

Select “Save/Restore Record”
from the “Setup Menu”

1.RECORD ID

.

2.TEST VOLTAGE
3.TEST FREQUENCY
4.PRINT RECORD
5.SAVE/RESTORE RECORD
6.SET TIME

Press key number 5
Selection of 5 may be
made by turning the
Control Knob. Push
down Control Knob
after 5 is selected

3

Select “Erase Record” from the
“Save/Restore Menu”

1.RESTORE RECORD

.

2.SAVE RECORD
3.RECORD DIRECTORY
4.ERASE RECORD

Press key number 4
Selection of 4 may be
made by turning the
Control Knob. Push
down Control Knob
after 4 is selected

4

Select “Erase Single Record
Number” from the “Erase
Record Menu”

ERASE RECORD

1.ERASE SINGLE RECORD

.

2.ERASE ALL RECORDS

“STOP” TO EXIT

Press key number 1 or
push down on the
Control Knob

5

Enter record number to be
erased

ERASE RECORD
NUMBER:

Use keys 0-9 to enter
record number
(50 was entered)

6 Confirm

record

number

ERASE RECORD
NUMBER: 50

Press “ENTER” key
or push down Control
Knob to confirm
(50 was keyed)

7

Record erased from FLASH
EEPROM

ERASING RECORD
PLEASE WAIT…

Wait for next display

8

Record number erased from
FLASH EEPROM confirmation

RECORD NUMBER 50
ERASED!

Press any key or push
down Control Knob

9

Option to choose erasing single
or all test records

ERASE RECORD

1.ERASE SINGLE RECORD

.

2.ERASE ALL RECORDS

“STOP” TO EXIT

Press the “STOP” key
to return to “Main
Menu”