Summit T3‐8 PCI Express Multi‐Lane Protocol Analyzer User Manual

165

De‐skewing Data

Teledyne LeCroy

Figure 9.2: Captured Data Display

Other views are provided for timing measurements, marker placement, physical layer 
errors, captured symbol types, packets, events, and decoding of ordered sets and packets. 
You can view any or all displays simultaneously, using the Windows selection in the View 
menu. 

9.4 De-skewing

Data

By default, BitTracer recordings display captured data in a raw, time‐skewed format, 
across all lanes in both directions. Individual bytes are as they were captured on the 
recorded link, before the receiver device on the link (or the receiver logic on the PETracer 
analyzer) has performed lane‐to‐lane de‐skew operations.

You can manually skew the captured data, left or right, in increments of one symbol time, 
using the associated toolbar buttons.

You can automatically de‐skew an entire lane direction. First, left‐click on the direction in 
the data window. Then right‐click to display a popup menu. Then select Auto De‐Skew.

You can de‐skew only one direction for each right‐click operation. To automatically de‐
skew the opposite direction, first left‐click on that direction in the data window.

9.5 Data

Display

Formats

To display traffic in K/D symbol (with Running Disparity indicated), scrambled, 
descrambled, 10‐bit, and Binary code formats:

Use the toolbar.