5.22 Counter

Counters can be created for any specific event or for multiple events. Counters function 
similar to an event and are independent of the event, thus allowing greater flexibility. You 
can select a counter for any event and if both channels are selected you can set the 
counter to count upstream and downstream. Counters can be reset providing further 
flexibility. The counter once set lives in the State. In an Advance to Sequence state once 
the action proceeds from one sequence state to the next, the counter in the preceding 
state will stop and the counter in the current state will start.

There are two Counters for the Global State and four Counters for the Sequence State 
(see

 Figure 5.43 on page 92

).

Note:

It is an invalid configuration for some events when you try and set a counter and timer when 

both channels are selected.

Local Counter Action

You can set the Action of the Counter to Increment or 
Reset. The Counter increments by one and resets to its 
initial value. The default is No Action.

Global Timer

Set the Global Timer, there are two options available.

Global Timer Action

You can set the Action of the timer to Start or Reset. 
When you reset the timer it resets to it’s initial value. The 
default is No Action.

Global Counter

Set the Global Counter, there are two options available.

Global Counter Action

You can set the Action of the Counter to Increment or 
Reset. The Counter increments by one and resets to its 
initial value. The default is No Action.