4 deleting a counter, 23 timer – Teledyne LeCroy Summit T3-8 PCIe Multi-lane Protocol Analyzer User Manual User Manual
Page 107

Summit T3‐8 PCI Express Multi‐Lane Protocol Analyzer User Manual
95
Timer
Teledyne LeCroy
5.22.4 Deleting a Counter
To delete a counter
1. Right‐click on the Counter.
2. Select Delete This Event. The counter will disappear from the event.
5.23 Timer
The Timer has two options which are Start and Reset (see
). When
set to Start it starts the timer and when set to Reset it resets the timer to its initial value.
When the timer count is down to 0 the action is triggered.
The Global State timer can trigger, start an action. It can also affect some other timers and
counters.
Note:
It is an invalid configuration for some events when you try and set a counter and timer when
both channels are selected.
The timers have different colors for the Global State and Sequence State. Each color
signifies a different meaning in the Global and Sequence states.
There are two Timers for the Global State and four Timers for the Sequence State.
Note:
Global timers/counters can be used by events from any direction as long as the events occur
more than 380 ns apart. State timer/counters can be controlled only from one direction not
both, meaning starting, reset and incrementing must be done from events occurring in the same
direction of the selected timer/counter.