Sdarefclk – Teledyne LeCroy WavePro Automation Command User Manual
Page 382

Automation Command and Query Reference Manual - Control Reference
UpSampleRefClk
Integer
From 1 to 50 step 1
Range
In some (rare) cases the clock signal may have a very fast edge relative to the scope's sample rate,
such that there are fewer than four samples on an edge. If that is so, it may help to reduce jitter on the
recovered clock to "upsample" the reference clock input. Determining the edge time uses cubic
interpolation, which works best when there are at least four samples on the edge. This control allows
you to specify the upsampling factor for the reference clock. In most cases, no upsampling is
needed. Nonetheless the default value for this control is 5, which should always be sufficient.
Description
SDAREFCLK
app.SDA2.RefClkInput.SDARefClk
AxisXRotation
Integer
From -90 to 90 step 1
Range
AxisYRotation
Integer
From -90 to 90 step 1
Range
This control is used only when Persisted is true and Persistence3d is true. It controls rotation about
the Y axis of the view being persisted.
Description
ClearSweeps
Action
Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.
Description
AxisXRotation
Integer
AxisYRotation
Integer
ClearSweeps
Action
LabelsPosition
String
LabelsText
String
Persist3DQuality
Enum
PersistDotJoined
Bool
Persisted
Bool
Persistence3d
Bool
PersistenceMonoChrome
Bool
PersistenceSaturation
Integer
PersistenceTime
Enum
ShowLastTrace
Bool
UseGrid
String
View
Bool
ViewLabels
Bool
1-368