Result, Tieraw – Teledyne LeCroy WavePro Automation Command User Manual
Page 309

Automation Command and Query Reference Manual - Control Reference
View
Bool
Sets/Queries the trace's 'Viewed' state. When true, the trace is displayed on one of the display
graticules. Note that even when a trace is not visible, it may be used as a source for Math, Measure,
etc.
Description
RESULT
app.SDA2.JitterMeasure.Parameters.TIEeye.Out.Result
TIERAW
app.SDA2.JitterMeasure.Parameters.TIEraw
ClearSweeps
Action
Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.
Description
View
Bool
Sets/Queries the trace's 'Viewed' state. When true, the trace is displayed on one of the display
graticules. Note that even when a trace is not visible, it may be used as a source for Math, Measure,
etc.
Description
ClearSweeps
Action
View
Bool
RESULT
app.SDA2.JitterMeasure.Parameters.TIEraw.Out.Result
TJ
app.SDA2.JitterMeasure.Parameters.Tj
Tj, Total Jitter, is an extrapolation based on Rj and Dj computed according to the jitter decomposition model (see
app.SDA2.JitterMeasure.Parameters.JitterModel), and combined according to the usual Dual Dirac formula: TJ = DJ
+ n * RJ, where n is a function of the probability of error set by the user. In many standards TJ is computed at a
probability of error of 1*10^-12. See app.SDA2.JitterMeasure.Parameters.BERPow10.
ClearSweeps
Action
Clear any accumulated result data. Useful for example to restart an average, or parameter statistics.
Description
ClearSweeps
Action
View
Bool
1-295
918501 RevA