beautypg.com

IAI America ERC User Manual

Page 62

background image

42


[2] When the control board is of the PNP specification [source type]














































[1] Insulate the power supply

[2] Change to NPN

Input common

0 V

24 V

Output common

24 V

0 V

(Note) To release the brake, connect a switch between the TB1-BK terminal and 24 V and turn on the switch.

MC

60 mA Max

TB2

EMG2

EMG1

24V

0V

FG

TB1

A

B

TB2

A

B

TB1

EMS2

EMS1

BK

MP

24V

0V

TB4

FG

TB3

J1

24V

0V

FG

EMG signal

Input power supply

Host system

MC

(Not used)

Twisted pair

Connect to FG

Relay cable

Motor drive power supply

Control power supply

Contact output for EMG
switch on teaching pendant

Insulated PIO terminal block (RCB-TU-PIO-AP/BP)

1

2

3

4

5

6

7

8

9

10

11

12

Outpu

t

side

Inpu

t

side

Brake release
switch

Output

common

Input

common

SIO converter (RCB-TU-SIO-A/B)

I/O interface

(Refer to 4.4, “Insulated PIO
Terminal Block.”)

(Note)

Relay