Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 98

background image

88

H-Class

Advanced Entry Calibration (continued)

Step

Action

Displayed Message

Comment

N

Press the ESC Key.


Use the buttons to scroll

to PAPER SENSOR LEVEL
(or if using reflective

media, REFL PAPER
LEVEL) and then press

ENTER.

Use the buttons to set the

Paper value determined in
Step M and then press

ENTER.

PAPER SENSOR LEVEL

(0 - 255)

173

This is the Paper value.

O

Press the ESC Key.

Scroll to GAP SENSOR
LEVEL (or, if using

reflective media, MARK
SENSOR LEVEL) and then

press ENTER.

Set the Gap (or Mark)

value determined in Step
M and then press ENTER.

GAP SENSOR LEVEL

(0 - 255)

042

This is the Gap (or Mark)
value.

P

Press the ESC Key.


Scroll to EMPTY SENSOR

LEVEL and then press
ENTER.


Set the Empty value

determined in Step M and
then press ENTER.

EMPTY SENSOR LEVEL

(0 - 255)

009

This is the Empty value.

Q

Press the EXIT Key and,

when prompted, press
YES at the SAVE

CHANGES prompt.

OFFLINE

The procedure is

finished, the process
almost complete.