beautypg.com

Datamax-O'Neil H-Class Operator’s Manual User Manual

Page 47

background image

H-Class

37

Media Settings (continued)

Menu Item

Details

PRINTHEAD CLEANING

Controls printhead cleaning alerts and functions,
where:

CLEAN HEAD SCHEDULE
0 – 200 in.(* 1000)
000

Specifies the inch (or centimeter) count (multiplied by

one thousand) at which to clean the printhead. If this
count is exceeded three times, a Head Cleaning Fault

will occur.

Zero (000) disables this function.

CLEAN HEAD COUNTER

Indicates the number of inches (or centimeters) since

a cleaning was last initiated.

RESET COUNTER

Allows the Clean Head Schedule to restart the count,

where:

YES

Resets the CLEAN HEAD COUNTER.

NO

Exits the menu item without changing the current

setting.

CLEAN HEAD NOW

Allows cleaning to begin, where:

YES

Initiates the cleaning process and resets the Clean
Head Counter (see Section 5.5.1).

NO

Exits the menu item without cleaning.