117

Fault Messages (continued)

Displayed Message

Description

Possible Solution(s)

TOP OF FORM FAULT

The printer could not find
a TOF mark within the

maximum length setting,
or TOF was encountered

in an unexpected place.

When the SENSOR

TYPE is REFLECTIVE,

this indication is
given for Out Of
Stock.

Check the following
possibilities:

Calibration may be

necessary (see Section

3.4);

The Media Sensor may need

adjustment (see Section
3.2);

The Media Guide may need

adjustment (see Section
3.1);

The Leveling Cam may need

adjustment (see Section

5.4.1);

The MAXIMUM LABEL

LENGTH may need to be
increased (see Section

4.2.1); or

The Media Sensor may need

to be cleaned (see Section
5.5.4).




6.2 Hex Dump Mode

Hex Dump Mode is a useful tool for diagnosing problems and debugging label formats as

received host data strings are printed without interpretation by the printer. These strings
can be analyzed for content and, by repeatedly sending a format, handshaking problems

(sections of missing data) can become apparent.

To enter Hex Dump Mode, press the MENU Button and select DIAGNOSTICS. Go to
HEX DUMP MODE then select ENABLE and press the ENTER Key. Exit the menu,
saving your changes.

Afterward, HEX DUMP MODE will be displayed and all received data will be output in
hexadecimal code (along with the ASCII equivalents), printed or saved to a file (see

FILE CAPTURE, Section 4.2.6). The example below illustrates a Hex Dump label
output: